W22Xdb Flameproof (Ex db) Motor
WEGElectric MotorsW22Xdb

W22Xdb Flameproof (Ex db) Motor

WEG W22Xdb flameproof motor from 0.12 to 370 kW in IEC frames 71–355, ATEX/IECEx certified for Zone 1 and 2 gas atmospheres.

Specifications

Output
0.12–370 kW
Frame sizes
IEC 71–355
Type of protection
Ex db (Ex db eb, Ex db / Ex tb optional)
Hazardous area
Zones 1 and 2, gas groups IIA and IIB (IIC, Group I optional)
Temperature class
T4 (T5, T6 optional)
Certification
ATEX / IECEx (BASEEFA or INERIS)
Efficiency class
IE2 standard (IE1, IE3, IE4 optional)
Voltage
Up to 690 V
Degree of protection
IP56 (IP66 optional)
Ambient temperature
–20 °C to +40 °C (–55 °C to +80 °C optional)
Thermal protection
Winding thermistors (standard)
Paint
Polyurethane, ISO 12944 C3

W22Xdb brings the design concept of W22 general-purpose motors to hazardous areas as a flameproof (Ex db) line. The enclosure is built to stop an internal explosion from spreading into the surrounding explosive atmosphere. The standard version is suitable for Zones 1 and 2, gas groups IIA and IIB, temperature class T4, and is ATEX and IECEx certified by BASEEFA or INERIS.

IE2 efficiency is standard, with IE3 and IE4 available as options. Output, speed and frame ratios follow IEC 60034 and 60072, ensuring interchangeability with the earlier WEG W21 flameproof range. IP56 protection, space heaters, winding thermistors and a polyurethane finish to ISO 12944 C3 are fitted as standard.

The WISE® insulation system allows drive operation up to 690 V, with insulated bearings and shaft grounding rings available. On request, Ex db eb, Ex db/Ex tb, gas group IIC, Group I mining and T5/T6 versions can be supplied. Euronorm supports W22Xdb selection for your hazardous area classification and provides quotations.

Features

Ex db flameproof enclosure

The enclosure prevents an internal explosion from propagating, enabling safe use in Zones 1 and 2.

ATEX and IECEx certified

Certification by BASEEFA or INERIS supports use in international projects.

IE2 standard, up to IE4

IE2 efficiency is standard, with IE3 and IE4 options available.

Rich standard equipment

IP56 protection, space heaters, winding thermistors and C3 polyurethane paint come as standard.

Drive operation

WISE® insulation allows variable frequency drive operation up to 690 V.

Easy maintenance

Integrally cast feet, double-drilled holes and grease fittings from frame 160 simplify service.

Applications

  • Oil and gas facilities and refineries
  • Chemical and petrochemical plants
  • Offshore platforms
  • Underground mining with the Group I version

Get a quote for this product